Electronic apex locator: Principles, Evolution, Comparative analysis, and clinical applications in Endodontics
Keywords:
electronic apex locator, impedance, root canal treatment, working lengthAbstract
Electronic apex locators are devices designed to determine root canal working length by measuring changes in electrical impedance within the canal. Since the initial concept based on electrical circuit principles introduced in 1918, electronic apex locators technology has advanced significantly. Contemporary devices employ multi-frequency alternating current and algorithm-based signal processing to improve accuracy. This review article aims to provide a comprehensive overview of electronic apex locators, including their working principles, generational development, factors affecting measurement accuracy, and recent technological innovations that enhance the efficacy of working length determination in endodontic procedures.
References
Ricucci D, Siqueira JF, Jr. Biofilms and apical periodontitis: study of prevalence and association with clinical and histopathologic findings. J Endod. 2010;36:1277-88.
Gulabivala K, Ng YL. Factors that affect the outcomes of root canal treatment and retreatment—A reframing of the principles. Int Endod J. 2023;56:82-115.
Ng YL, Mann V, Gulabivala K. A prospective study of the factors affecting outcomes of nonsurgical root canal treatment: part 1:
periapical health. Int Endod J. 2011;44:583-609.
Gambarini G, Krastl G, Chaniotis A, et al. Clinical challenges and current trends in access cavity design and working length determination: First European Society of Endodontology (ESE) clinical meeting: ACTA, Amsterdam, The Netherlands, 27th October
Int Endod J. 2019;52:397-9.
Hany M. A. Ahmed aPMHD. Endodontic Advances and Evidence-Based Clinical Guidelines. USA: John Wiley & Sons; 2022.
Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc. 1955;50:544-52.
Pineda F, Kuttler Y. Mesiodistal and buccolingual roentgenographic investigation of 7,275 root canals. Oral Surg Oral Med Oral Pathol.
;33:101-10.
Orosco FA, Bernardineli N, Garcia RB, et al. In vivo accuracy of conventional and digital radiographic methods in confirming root canal working length determination by Root ZX. J Appl Oral Sci. 2012;20:522-5.
Mohan M, Verma MR, Jain AK, et al. Comparison of Accuracy of Dentaport ZX, Rootor and E-Pex Pro Electronic Apex Locators in Two
Simulated Clinical Conditions: An In Vitro Study. J Conserv Dent. 2022;25:58-62.
Martínez-Lozano MA, Forner-Navarro L, Sánchez-Cortés JL, et al. Methodological considerations in the determination of working
length. Int Endod J. 2001;34:371-6.
Mahmoud O, Awad Abdelmagied MH, Dandashi AH, et al. Comparative Evaluation of Accuracy of Different Apex Locators: Propex IQ,
Raypex 6, Root ZX, and Apex ID with CBCT and Periapical Radiograph-In Vitro Study.
Int J Dent. 2021;2021:5563426.
Stein TJ, Corcoran JF. Anatomy of the root apex and its histologic changes with age. Oral Surg Oral Med Oral Pathol. 1990;69: 238-42.
Malueg LA, Wilcox LR, Johnson W. Examination
of external apical root resorption with scanning electron microscopy. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1996;
:89-93.
Berman LH, Hargreaves KM. Cohen's pathways of the pulp. 12th ed.: Elsevier Health Sciences; 2020.
Saha D, Mazumdar D, Biswas M, et al. Comparative evaluation of efficacy in working length determination: Radiography versus
Electronic apex locators using in vivo and ex vivo methods with stereomicroscope validation. J Conserv Dent Endod. 2024;
:790-4.
Kaur G, Thomas AR, Samson RS, et al. Efficacy of electronic apex locators in comparison with intraoral radiographs in working length
determination- a systematic review and metaanalysis. BMC Oral Health. 2024;24:532.
Kim E, Marmo M, Lee CY, et al. An in vivo comparison of working length determination by only root-ZX apex locator versus combining root-ZX apex locator with radiographs using a new impression technique. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2008; 105:e79-83.
Custer LE. Exact Method of Locating the Apical Foramen. Dent Regist. 1918;72:420-5.
Suzuki K. Experimental study on iontophoresis. Jpn J Stomatol. 1942;16:411–29.
Sunada I. New method for measuring the length of the root canal. J Dent Res. 1962;41:375–87.
Nekoofar MH, Ghandi MM, Hayes SJ, et al. The fundamental operating principles of electronic root canal length measurement
devices. Int Endod J. 2006;39:595-609.
Huang J-H, Yen S-C, Lin C-P. Impedance Characteristics of Mimic Human Tooth Root Canal and Its Equivalent Circuit Model.
J Electrochem Soc. 2008;155:P51.
Dahlin J. Electrometric measuring of the apical foramen. A new method for diagnosis and
endodontic therapy. Quintessence Int Dent Dig. 1979;10:13-22.
Dimitrov S, Roshkev D. Sixth generation adaptive apex locator. Journal of IMAB-Annual Proceeding (Scientific Papers). 2009;15:75-8.
ROOT ZX II Canal Measurement Module: Operation Instructions. J MORITA MFG CORP. Japan2012.
Hoer D, Attin T. The accuracy of electronic working length determination. Int Endod J. 2004;37:125-31.
Ounsi HF, Naaman A. In vitro evaluation of the reliability of the Root ZX electronic apex locator. Int Endod J. 1999;32:120-3.
Shabahang S, Goon WW, Gluskin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod. 1996;22:616-8.
Dunlap CA, Remeikis NA, BeGole EA, et al. An in vivo evaluation of an electronic apex locator that uses the ratio method in vital
and necrotic canals. J Endod. 1998;24:48-50.
Vajpayee A, Khandare PD, Dutta SD, et al. In vivo Study to Evaluate the Effect of Instrument Size on the Accuracy of Three Different
Apex Locators when Various Irrigation Solutions are used in Vital and Non-Vital Teeth. J Pharm Bioallied Sci. 2023;15:S1156-s9.
Saritha V, Raghu H, Kumar TH, et al. The accuracy of two electronic apex locators on effect of preflaring and file size: An in vitro study. J Conserv Dent. 2021;24:46-9.
Siddiqui AY, Alothmani OS. Influence of Hand File Size on the Accuracy of Root ZX and iPex Electronic Apex Locators: An In Vitro Study. Cureus. 2023;15:e39662.
de Camargo EJ, Zapata RO, Medeiros PL, et al. Influence of preflaring on the accuracy of length determination with four electronic
apex locators. J Endod. 2009;35:1300-2.
Heo KY, Hwang HK, Jo HH. Accuracy of electronic apex locators using heat-treated Ni-Ti file. Aust Endod J. 2023;49:111-6.
Kaufman N, Fux Noy A, Slutzky-Goldberg I. A Comparative Ex Vivo Study on Apex Locator Precision in Mature Teeth and Immature Teeth With Divergent Canals. Cureus. 2024;16: e69116.
Kim YJ, Chandler NP. Determination of working length for teeth with wide or immature apices: a review. Int Endod J. 2013;46:
-91.
Ebrahim AK, Yoshioka T, Kobayashi C, et al. The effects of file size, sodium hypochlorite and blood on the accuracy of Root ZX apex
locator in enlarged root canals: an in vitro study. Aust Dent J. 2006;51:153-7.
Herrera M, Abalos C, Planas AJ, et al. Influence of apical constriction diameter on Root ZX apex locator precision. J Endod. 2007;33:
-8.
Ebrahim AK, Wadachi R, Suda H. Ex vivo evaluation of the ability of four different electronic apex locators to determine the working length in teeth with various foramen diameters. Aust Dent J. 2006;51:258-62.
ElAyouti A, Kimionis I, Chu AL, et al. Determining the apical terminus of root-end resected teeth using three modern apex locators:
a comparative ex vivo study. Int Endod J. 2005;38:827-33.
Herrera M, Ábalos C, Lucena C, et al. Critical diameter of apical foramen and of file size using the Root ZX apex locator: an in vitro study. J Endod. 2011;37:1306-9.
Broon NJ, Palafox-Sánchez CA, Estrela C, et al. Analysis of Electronic Apex Locators in Human Teeth Diagnosed With Apical Periodontitis. Braz Dent J. 2019;30:550-4.
Hasheminia SM, Jahadi S, Moghaddam FG, et al. Comparison of the accuracy of apex locator, digital radiography, and cone-beam computed tomography in root canal working length determination in teeth with external root resorption: An in vitro study. Dent Res J
(Isfahan). 2024;21:8.
Adibi A, Sobhnamayan F, Ostovar Zijerdi N, et al. Comparison of the Accuracy of CBCT Images and Apex Locator in Detection of External Root Resorption with Perforation. J Dent (Shiraz). 2022;23:445-51.
Tufenkci P, Kalaycı A. Evaluation of the accuracy of different apex locators in determining the working length during root canal retreatment. J Dent Res Dent Clin Dent Prospects. 2020; 14:125-9.
Nasiri K, Wrbas KT. Accuracy of different generations of apex locators in determining working length; a systematic review and
meta-analysis. Saudi Dent J. 2022;34:11-20.
Sayed A, Dighole S, Lobo WMV, et al. Comparative evaluation of the accuracy of six different apex locators in working length determination of molars using intraoral periapical radiographs: An in vivo study. J Conserv Dent Endod. 2024; 27:695-700.
Brand L, Dunlap CA, Scott R, et al. An in vitro evaluation of the WIRELE-x electronic apex locator. Aust Endod J. 2023;49 Suppl 1:41-5.
Abidi SYA, Azfar M, Nayab T, et al. Accuracy of working length measurement with endo motor having built-in apex locator and comparison with periapical radiographs. J Pak Med Assoc. 2020;70:437-41.
Klemz AA, Cruz ATG, Piasecki L, et al. Accuracy of electronic apical functions of a new integrated motor compared to the visual control of the working length-an ex vivo study. Clin Oral Investig. 2021;25:231-6.
Topuz O, Uzun O, Tinaz AC, et al. Accuracy of the apex locating function of TCM Endo V in simulated conditions: a comparison study.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2007;103:e73-6.
Barakat RM, Almohareb RA, Alharbi AO, et al. Comparative Accuracy and Reliability of Three Electronic Apex Locators in Determining the Apical Constriction of Molar Canals: A Micro-CT Evaluation. J Clin Med. 2024;13.
Parirokh M, Manochehrifar H, Shahravan A, et al. The Effect of Long Service Life on the Accuracy of Dentaport ZX Electronic Apex Locator. Iran Endod J. 2022;17:195-9.
Cîmpean SI, Chisnoiu RM, Colceriu Burtea AL, et al. In Vitro Evaluation of the Accuracy of Three Electronic Apex Locators Using
Different Sodium Hypochlorite Concentrations. Medicina (Kaunas). 2023;59.
Monisha R, Sivakumar A, Chittrarasu M, et al. Comparative evaluation of accuracy of working length determination with fifth-generation apex locator using two different techniques: An in vitro study. J Conserv Dent Endod. 2024; 27:240-5.
Tsesis I, Blazer T, Ben-Izhack G, et al. The Precision of Electronic Apex Locators in Working Length Determination: A Systematic
Review and Meta-analysis of the Literature. J Endod. 2015;41:1818-23.
Çınar F, Üstün Y. Ex Vivo Evaluation of the Accuracy of 3 Electronic Apex Locators in Different Environments: A Micro-Computed
Tomography Study. Eur Endod J. 2020;5: 226-30.
Yahya EM, Alchalabi AS, Alkhalidi EF. Effect of Different Electroconductive Root Canal Irrigations on the Accuracy of Different Apex Locators: An In Vitro Comparative Study. J Int Soc Prev Community Dent. 2024;14: 211-7.
Karunakar P, Reddy MSR, Faizuddin U, et al. Comparative evaluation of working length determined using integrated apex locator and root ZX mini under various irrigating solutions: An in vivo study. J Conserv Dent Endod. 2023; 26:590-4.
Adorno CG, Solaeche SM, Ferreira IE, et al. The influence of periapical lesions on the repeatability of two electronic apex locators
in vivo. Clin Oral Investig. 2021;25:5239-45.
Kowollik S, Sonntag D. Accuracy and consistency of electronic root canal length determination with electrically isolating rubber stoppers. Aust Endod J. 2019;45:33-9.
Jakovac M, Žic M, Pavić L, et al. Electrical Properties of Two Types of Lithium-Based Glass Ceramics. Acta Stomatol Croat. 2022;
(3):281-7.
Borik MA, Chislov AS, Kulebyakin AV, et al. Data on physical and electrical properties of (ZrO(2))(1-x)(Sc(2)O(3))(x)(CeO(2))(y)
and (ZrO(2))(1-x-y-z)(Sc(2)O(3))(x)(CeO(2))(y) (Y(2)O(3))(z) solid solution crystals. Data Brief. 2019;25:104061.
Sidhu P, Shankargouda S, Dicksit DD, et al. Evaluation of Interference of Cellular Phones on Electronic Apex Locators: An In Vitro Study. J Endod. 2016;42:622-5.
Silva E, Muniz B, Carvalho N, et al. Electromagnetic interference of smartphones on apex locators: An in vivo study. ENDO. 2016;10:161-5.
Niu Y, Chen Y, Li W, et al. Electromagnetic interference effect of dental equipment on cardiac implantable electrical devices:
A systematic review. Pacing Clin Electrophysiol. 2020;43:1588-98.
Beach CW, Bramwell JD, Hutter JW. Use of an electronic apex locator on a cardiac pacemaker patient. J Endod. 1996;22:182-4.
AlRahabi MK, Ghabbani HM. Influence and safety of electronic apex locators in patients with cardiovascular implantable electronic
devices: a systematic review. Libyan J Med. 2019;14:1547071.
Eren İ, Deniz Y. The usefulness of ultrasonography as a dynamic measurement system for visualizing root canal working length: an in vivo study. BMC Oral Health. 2024;24:801.
Eren İ, Sarıyılmaz Ö, Eren H, et al. Can ultrasonography be used to determine working length in endodontic treatment? An in
vitro study. Odontology. 2024;112:453-9.
Lai G, Dunlap C, Gluskin A, et al. Artificial Intelligence in Endodontics. J Calif Dent Assoc. 2023;51.
Umer F, Habib S. Critical Analysis of Artificial Intelligence in Endodontics: A Scoping Review. J Endod. 2022;48:152-60.
Aminoshariae A, Kulild J, Nagendrababu V. Artificial Intelligence in Endodontics: Current Applications and Future Directions. J Endod.
;47:1352-7.
Ourang SA, Sohrabniya F, Mohammad-Rahimi H, et al. Artificial intelligence in endodontics: Fundamental principles, workflow, and tasks. Int Endod J. 2024;57:1546-65.
Khanagar SB, Alfadley A, Alfouzan K, et al. Developments and Performance of Artificial Intelligence Models Designed for Application in Endodontics: A Systematic Review. Diagnostics (Basel). 2023;13.
Ahmed ZH, Almuharib AM, Abdulkarim AA, et al. Artificial Intelligence and Its Application in Endodontics: A Review. J Contemp Dent Pract. 2023;24:912-7.
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2025 Thai Endodontic Journal

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Thai Endod Journal is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0) license, unless otherwise stated. Please read our Policies in Copyright for more information.