Efficacy of Normal Saline for Sealing the Needle Tract to Reduce Pneumothorax Incidence after Transthoracic Needle Lung Biopsies

ผู้แต่ง

  • Panat Nisityotakul Department of Radiology, Vachira Phuket Hospital, Phuket, Thailand
  • Wankarn Boonlorm Department of Radiology, Vachira Phuket Hospital, Phuket, Thailand

คำสำคัญ:

Lung Biopsy, , TTNB, , Transthoracic Needle Biopsy,, Pneumothorax, , Normal Saline Tract Embolization

บทคัดย่อ

Background: Pneumothorax is a frequent complication of transthoracic needle biopsy (TTNB) procedures, often necessitating chest tube placement and hospitalization. The demand for lung biopsies is increasing due to the rising incidence of lung cancer and the identification of asymptomatic lung nodules, escalating the economic burden associated with complex lung biopsy procedures. Various techniques have been explored to reduce pneumothorax incidences in TTNB, including rapid rollover, autologous blood patch, fibrin gel plug, and normal saline sealant. However, there is no consensus on the most effective method.

Objective: The study evaluates the benefit of employing normal saline solution (NSS) tract embolization to reduce iatrogenic pneumothorax.

Material and method: This descriptive retrospective study was conducted at Vachira Phuket Hospital from January 2021 to September 2023. A total of 64 patients undergoing lung biopsies with and without NSS were compared. In the NSS group, 1-3 ml of normal saline was injected while withdrawing the coaxial sheath after the biopsy.

Result: Post-biopsy outcomes revealed a slight reduction in pneumothorax rates in the NSS group (18.8%, 6/32 patients) compared to the control group (31.2%, 10/32 patients), but this difference was not statistically significant (P=0.693). The need for pneumothorax chest drain (PCD) placement was marginally lower in the NSS group (3.1%, 1/32 patients) than in the control group (9.4%, 3/32 patients), indicating chest tube insertion in cases of severe pneumothorax (more than 4 cm in CXR measurement) or if the patient developed dyspnea. However, this difference did not reach statistical significance (P=0.613).

Conclusion: While the NSS group exhibited a trend towards lower pneumothorax rates and decreased chest tube insertions post-biopsy, these differences did not reach statistical significance. Further research with larger sample sizes and refined methodologies, such as randomized controlled trials, is warranted to elucidate the role of NSS in TTNB procedures.

References

Gupta, S., et al., Quality improvement guidelines for percutaneous needle biopsy. J Vasc Interv Radiol, 2010. 21(7): p. 969-75.

Manhire, A., et al., Guidelines for radiologically guided lung biopsy. Thorax, 2003. 58(11): p. 920-36.

Heerink, W.J., et al., Complication rates of CT-guided transthoracic lung biopsy: meta-analysis. Eur Radiol, 2017. 27(1): p. 138-148.

Gurley, M.B., W.R. Richli, and K.A. Waugh, Outpatient management of pneumothorax after fine-needle aspiration: economic advantages for the hospital and patient. Radiology, 1998. 209(3): p. 717-22.

Li, Y., et al., CT-guided percutaneous core needle biopsy for small (=20 mm) pulmonary lesions. Clin Radiol, 2013. 68(1): p. e43-8.

Huo, Y.R., et al., Post-Biopsy Manoeuvres to Reduce Pneumothorax Incidence in CT-Guided Transthoracic Lung Biopsies: A Systematic Review and Meta-analysis. Cardiovasc Intervent Radiol, 2019. 42(8): p. 1062-1072.

Graffy, P. et al., Pulmonary Intraparenchymal Blood Patching Decreases the Rate of Pneumothorax-Related Complications Following Percutaneous CT-Guided Needle Biopsy. J Vasc Interv Radiol, 2017. 28(4): p. 608-613 e1.

Clayton, J.D. et al., Nonclotted Blood Patch Technique Reduces Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsies. J Thorac Imaging, 2016. 31(4): p. 243-6.

Petsas, T., et al., Fibrin glue for sealing the needle track in fine-needle percutaneous lung biopsy using a coaxial system: Part II--Clinical study. Cardiovasc Intervent Radiol, 1995. 18(6): p. 378-82.

Engeler, C.E., et al., Pneumothorax after lung biopsy: prevention with transpleural placement of compressed collagen foam plugs. Radiology, 1992. 184(3): p. 787-9.

Billich, C., et al., CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track. Eur Radiol, 2008. 18(6): p. 1146-52.

Li, Y., et al., Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy. Clin Radiol, 2015. 70(11): p. 1192-7.

Akkakrisee, S. and K. Hongsakul, Percutaneous transthoracic needle biopsy for pulmonary nodules: a retrospective study of a comparison between C-arm cone-beam computed tomography and conventional computed tomography guidance. Pol J Radiol, 2020. 85: p. e309-e315.

Yamagami, T., Toshiyuki Nakamura, Shigeharu Iida, Takeharu Kato, and Tsunehiko Nishimura. “Management of Pneumothorax After Percutaneous CT-Guided Lung Biopsy.” Chest 121, no. 4 (April 1, 2002): 1159–64. https://doi.org/10.1378/chest.121.4.1159, .

Yeow, K.-M., I.-Hao Su, Kuang-Tse Pan, Pei-Kwei Tsay, Kar-Wai Lui, Yun-Chung Cheung, and Andy Shau-Bin Chou. “Risk Factors of Pneumothorax and Bleeding: Multivariate Analysis of 660 CT-Guided Coaxial Cutting Needle Lung Biopsies.” Chest 126, no. 3 (2004): 748–54. https://doi.org/10.1378/chest.126.3.748, .

Saji, H., Haruhiko Nakamura, Takaaki Tsuchida, Masahiro Tsuboi, Norihiko Kawate, Chimori Konaka, and Harubumi Kato. “The Incidence and the Risk of Pneumothorax and Chest Tube Placement After Percutaneous CT-Guided Lung Biopsy: The Angle of the Needle Trajectory Is a Novel Predictor.” Chest 121, no. 5 (May 1, 2002): 1521–26. , .

Downloads

เผยแพร่แล้ว

30-06-2024

How to Cite

Nisityotakul , P. ., & Boonlorm, W. . (2024). Efficacy of Normal Saline for Sealing the Needle Tract to Reduce Pneumothorax Incidence after Transthoracic Needle Lung Biopsies. วารสารวิทยาศาสตร์สุขภาพและสาธารณสุข วชิระภูเก็ต, 4(1), 1–10. สืบค้น จาก https://he03.tci-thaijo.org/index.php/VCHPK/article/view/3941

Similar Articles

You may also start an advanced similarity search for this article.